Heat stress

WBGT Calculator (Wet Bulb Globe Temperature)

Compute WBGT from wet-bulb, globe and air temperatures for heat-stress screening.

Live calculator

WBGT Calculator

WBGT = 0.7·Tw + 0.2·Tg + 0.1·Ta

Wet Bulb Globe Temperature

—

Enter natural wet-bulb and globe temperatures.

Wet Bulb Globe Temperature (WBGT) is the preferred screening index for occupational heat stress in ISO 7243 and ACGIH TLVs. It combines humidity effects (natural wet-bulb temperature Tw), radiant heat (globe temperature Tg) and air temperature (Ta) into one value you can compare against workload-based limits.

This calculator applies the standard weighting equations. It does not replace a full heat-stress assessment, physiological monitoring, or emergency response when someone shows signs of heat illness.

Key points

Before you run the numbers, keep these rules of thumb in mind — they prevent the most common reporting mistakes.

  • Measure at the breathing zone of the hottest work location.
  • Apply clothing adjustment factors for chemical suits and multi-layer PPE.
  • Unacclimatised workers need more protective action levels.
  • Stop-work criteria for heat illness symptoms override any calculated WBGT.

Formula

WBGT combines humidity, radiant heat and air temperature into one screening index. Choose the outdoor (solar) equation when workers are in sun; use the indoor / no-solar equation when radiant solar load is negligible.

Formula. Outdoor (solar): 0.7·Tw + 0.2·Tg + 0.1·Ta · Indoor / shade: 0.7·Tw + 0.3·Tg

Used by industrial hygienists, construction and outdoor-work supervisors managing heat stress.

Variables explained

Each term in the equation must use the same reporting period and workforce boundary.

Symbol / inputWhat to enter
TwNatural (unaspirated) wet-bulb temperature.
TgBlack globe temperature (typically 150 mm globe).
TaDry-bulb air temperature (outdoor / solar formula only).

How to use this calculator

Measure correctly first — a perfect equation on bad sensor placement still gives a dangerous answer.

1. Measure Tw, Tg and Ta

Use a WBGT meter or separate sensors: natural wet-bulb, 150 mm black globe, and shielded dry-bulb.

  • Place instruments at the breathing zone of the hottest work location.
  • Allow sensors to equilibrate before logging.

2. Choose indoor or outdoor formula

With solar load, use 0.7·Tw + 0.2·Tg + 0.1·Ta. Indoors or outdoors without solar load, use 0.7·Tw + 0.3·Tg.

3. Compare to the exposure limit

Look up the ACGIH TLV or ISO reference value for the metabolic rate (workload) and clothing adjustment. Implement work/rest cycles, hydration, shade and acclimatisation as required.

Interpreting the result

WBGT is a screening index. Compare it to workload-based limits in ACGIH TLVs or ISO 7243 — the calculator does not replace those tables.

Which WBGT equation to use
ConditionEquationWhen
Outdoor with sun0.7·Tw + 0.2·Tg + 0.1·TaDirect solar load on the worker
Indoor / shade0.7·Tw + 0.3·TgNo meaningful solar radiation

Screening, not diagnosis

WBGT screening assumes fit, acclimatised workers. Unacclimatised people, certain medications, PPE ensembles and radiant furnaces may need lower action levels or a detailed analysis.

Clothing adjustment

Chemical suits and multi-layer PPE add clothing adjustment factors to WBGT or reduce the allowable metabolic rate. Check the TLV booklet or ISO 7243 tables.

Worked example

Outdoor paving crew in direct sun.

  1. Tw = 28 °C, Tg = 42 °C, Ta = 34 °C.
  2. WBGT = 0.7×28 + 0.2×42 + 0.1×34 = 19.6 + 8.4 + 3.4 = 31.4 °C.

At 31.4 °C WBGT, heavy labour typically needs aggressive work/rest controls or stop-work per your heat-stress plan — confirm against the TLV for the actual metabolic rate and clothing.

ComponentContribution (°C)
0.7 × Tw19.6
0.2 × Tg8.4
0.1 × Ta3.4
WBGT31.4

Frequently asked questions

Supervisors often confuse WBGT with heat index — these answers keep the distinction clear.

What is the difference between WBGT and heat index?

Heat index combines air temperature and humidity for shade, and ignores radiant heat and workload. WBGT includes globe temperature and is the occupational screening index used with metabolic-rate limits.

Can I estimate WBGT from weather-station data alone?

Approximate methods exist, but they can miss local radiant loads (asphalt, furnaces, reflection). Prefer on-site WBGT measurements for compliance decisions.

Indoor vs outdoor WBGT formula — which do I use under a tent?

If solar radiation on the worker is negligible, use the indoor / no-solar formula (0.7·Tw + 0.3·Tg). If workers are in direct sun, use the outdoor formula.

Disclaimer. These calculators support training and internal KPI arithmetic. They are not legal advice, medical advice, or a substitute for your organisation's procedures, applicable standards, or a competent person's judgement. Confirm definitions and multipliers against your SMS and the code of record before reporting externally.