Twenty rules cover most of what keeps a laboratory safe. Wear the right protective equipment, read the label and the safety data sheet before touching a chemical, and work with volatile or toxic material inside a fume hood. Store chemicals that react together apart. Know where the eyewash, safety shower, fire extinguisher and spill kit are before you start work.
The 20 Lab Safety Rules

Each rule below stands on its own, and the sections that follow explain the hazard behind it. Learn the list before your first day at a bench. Check yourself against it whenever a new procedure, chemical or piece of equipment appears.
- Read the label and the safety data sheet before handling any chemical.
- Wear a lab coat, eye protection and gloves, and closed shoes, at all times in the lab.
- Tie back long hair and remove loose clothing and dangling jewellery before starting work.
- Never eat, drink, chew gum or apply cosmetics in the laboratory.
- Never pipette by mouth; use a mechanical pipetting device every time.
- Wash your hands after handling chemicals and before leaving the laboratory.
- Work with volatile, toxic or dusty chemicals inside a fume hood or a biosafety cabinet.
- Keep the fume hood sash as low as practical and never store chemicals inside the hood.
- Label every container with its contents and its hazard, including beakers left for later.
- Store chemicals that react together apart, and keep flammable liquids in a rated cabinet.
- Inspect glassware before use and discard any chipped, cracked or star-cracked piece.
- Put sharps straight into a sharps container and never recap a needle.
- Restrain gas cylinders upright, keep the cap on when not in use, and never oil a valve.
- Know where the eyewash, safety shower, fire extinguisher, spill kit and first-aid kit are.
- Flush eyes for 15 minutes after a splash, remove contaminated clothing, and get medical help.
- Report every spill, exposure, broken container and near miss at once, however small.
- Clean up only spills you are trained and equipped for; call for help with the rest.
- Keep benches clear and keep exits, aisles and safety equipment free of obstruction.
- Never work alone with highly hazardous material or outside staffed hours without approval.
- Follow the laboratory Chemical Hygiene Plan and get approval before a new or changed procedure.
Know the Hazards Before You Touch Anything

Every laboratory hazard falls into one of four families: chemical, biological, radiological and physical. Chemical hazards injure through contact, inhalation or ingestion; biological hazards infect or sensitise; radiological hazards irradiate; physical hazards cut, burn, crush or shock. A single procedure can carry all four at once, so name the hazard family before choosing controls.
The label on the container and the safety data sheet (SDS) are the first sources of hazard information. A GHS label carries a product identifier, hazard pictograms, a signal word, hazard statements, precautionary statements and supplier details. The SDS runs to 16 sections. It covers identification, hazard identification, first-aid measures, firefighting measures, accidental release measures, handling and storage, exposure controls and toxicological information. Read sections 2, 4, 5, 6, 7 and 8 before starting a new procedure, not after a problem appears.
| Hazard family | Examples | First control |
|---|---|---|
| Chemical | Flammable solvents, corrosive acids, toxic reagents | Read the label and SDS; use the fume hood |
| Biological | Bacteria, viruses, blood, cell cultures | Standard microbiological practice; biosafety cabinet |
| Radiological | Radioisotopes, X-ray equipment | Shielding, time, distance, monitoring |
| Physical | Glassware, sharps, compressed gas, electricity, heat | Inspection, guards, restraint, lockout |
Risk assessment comes before the work, not during it. Identify the hazards, decide who could be harmed and how, and judge the risk. Choose controls in hierarchy order, and record the assessment where the people doing the work can find it. A risk assessment that nobody reads is paperwork; one that changes how the bench is set up is a control. Review the assessment when the procedure, the scale or the people change.
WarningNever trust a chemical by its appearance or smell. Some of the most dangerous laboratory chemicals are colourless liquids with no odour, and odour fades as exposure continues. Check the label and the SDS instead.
The Chemical Hygiene Plan

In the United States, any employer whose staff use hazardous chemicals on a laboratory scale must have a written Chemical Hygiene Plan (CHP). The plan sits under OSHA's Laboratory Standard, 29 CFR 1910.1450. It sets out the procedures, equipment, protective equipment and work practices for that laboratory. They protect staff from the health hazards of its chemicals. It must be readily available to employees, their representatives and OSHA on request.
The standard lists eight elements the plan must contain. Standard operating procedures for each activity involving hazardous chemicals come first. Next come the criteria for choosing control measures: engineering controls, personal protective equipment and hygiene practices. Extremely hazardous materials get particular attention. The plan must require fume hoods and other protective equipment to function properly. It must name the specific measures that keep them that way.
- Standard operating procedures for each activity involving hazardous chemicals.
- Criteria for control measures: engineering controls, PPE and hygiene practices.
- A requirement that fume hoods and other protective equipment function properly.
- Information and training: the standard, the plan, exposure limits, signs and symptoms of exposure, and SDS locations.
- Circumstances that need prior approval from the employer or a supervisor.
- Designation of the people responsible, including a Chemical Hygiene Officer.
- Extra protection for particularly hazardous substances: select carcinogens, reproductive toxins and substances with a high degree of acute toxicity.
- Review and evaluation of the plan's effectiveness at least once a year, with updates as needed.
The Chemical Hygiene Officer is the named person for the plan. That person is qualified by training or experience to give technical guidance on developing and running it. A Chemical Hygiene Committee supports the officer where the organisation is large enough to need one. Particularly hazardous substances get extra controls: a designated work area, containment devices such as a fume hood or glove box, procedures for safe removal of contaminated waste, and decontamination procedures.
Training under the standard must cover three things: the methods and observations that reveal a chemical release; the physical and health hazards of the chemicals in the work area; and the measures that protect against them, such as work practices, emergency procedures and protective equipment. Medical consultation must be offered after three kinds of event: symptoms of exposure, monitoring above the action level or permissible exposure limit, and a spill, leak or explosion that could have caused exposure. OSHA training requirements set the baseline; the plan fills in the laboratory's own procedures.
AlertA Chemical Hygiene Plan that names a Chemical Hygiene Officer who left two years ago is out of date. Check the named people and the review date when you join a lab. Ask for the current plan if the copy on the shelf predates your arrival.
Personal Protective Equipment

Personal protective equipment (PPE) is the last line of defence in a laboratory. It is used after engineering controls and safe work practices have done all they can. OSHA's general PPE standard, 29 CFR 1910.132, requires the employer to assess the workplace hazards. The employer then selects the protective equipment that fits them. The laboratory's assessment decides what is worn for each task. The worker's job is to wear it correctly, every time, without exception for short jobs.
Eye and Face Protection
Safety glasses with side shields are the minimum eye protection in most laboratories. Chemical splash goggles replace them wherever splashing is possible: pouring, mixing, heating or working with corrosives. A face shield protects the face and neck from splashes and flying glass. It is worn over goggles, never instead of them, because liquid can run around its edges. Contact lenses are not eye protection. Wear safety glasses or goggles over them, and tell your supervisor you wear lenses so first aid can account for it.
Choose eye protection against the hazard, not the habit. Ordinary prescription glasses leave the sides of the eyes open and fail against splashes. Goggles with indirect ventilation resist fogging while keeping liquid out. Face shields rated for impact protect against glassware that fails under pressure or vacuum. Check lenses for scratches and frames for cracks before each use, and replace damaged eye protection at once.
Gloves
No single glove material protects against every chemical. Nitrile suits most laboratory work. Latex suits biological work but causes allergy in some people. Thicker reusable gloves suit cleaning and handling corrosives. Check the chemical's SDS and the glove manufacturer's chemical compatibility chart before choosing. Match the glove to the chemical, the task and the contact time. Safety gloves chosen by hazard, not by what is nearest the bench, are the ones that hold up.
Inspect gloves before putting them on. Look for tears, holes, thinning and discolouration, and inflate each glove gently to check for leaks. Remove gloves without touching the outside with bare skin, and wash hands straight after. Change gloves when they are torn, contaminated or past their use time for that chemical. Never wear laboratory gloves outside the laboratory. In offices, corridors, lifts or canteens they spread contamination to clean surfaces.
Lab Coats and Footwear
A lab coat protects skin and street clothing from splashes, and it must be fully buttoned, with sleeves down, whenever work is under way. Flame-resistant coats are needed where flammable liquids or open flames are used. Coats stay in the laboratory; they are never worn home, hung over office chairs, or stored with street clothes. Closed shoes with a low heel and a solid upper are required in every laboratory. No sandals, no trainers with mesh uppers, and no bare ankles near glassware and hot surfaces.
Remove the coat and gloves before leaving the laboratory, and wash your hands. Contaminated coats go into the marked laundry container, not into a personal bag. Long hair is tied back, loose sleeves are secured, and dangling jewellery and lanyards come off before work starts. Loose items catch on equipment, dip into chemicals and carry contamination out of the lab.
Housekeeping

Most laboratory accidents start with housekeeping, not with exotic chemistry. A cluttered bench hides a leaking bottle, a blocked aisle slows an escape, and a full waste container invites a spill. Clean benches, clear floors and labelled containers are safety controls, not tidiness for its own sake. Tidy the bench at the end of every procedure, and leave it ready for the next person.
- Keep benches clear of chemicals and equipment not in use.
- Keep aisles, exits and safety equipment free of boxes, bags and trolleys.
- Wipe up drips and spills at once, with the right materials for the chemical.
- Return chemicals to storage before leaving; never leave bottles on benches overnight.
- Label every container, including wash bottles, beakers and samples left for later.
- Wash hands before leaving the laboratory and before eating or drinking.
Food, drink, chewing gum and cosmetics have no place in a laboratory, and food is never stored in a laboratory refrigerator. A drink bottle on a bench can be mistaken for a reagent, and a sandwich absorbs vapours from the air. Separate refrigerators, marked for food only, must sit outside the laboratory. Mouth pipetting is prohibited in every laboratory. Mechanical pipetting devices are cheap, and mouth pipetting has poisoned and infected workers who thought they were careful.
TipTreat every unlabelled container as hazardous waste. If you find one, do not open it, smell it or pour it away. Report it to the lab supervisor so it can be identified and disposed of safely.
Using a Fume Hood Properly

A chemical fume hood protects the worker by drawing air away from the bench and exhausting it outside the building. It is the main engineering control for volatile, toxic and dusty chemicals. The Chemical Hygiene Plan must ensure it functions properly. A hood that is not working is worse than no hood at all. It gives a false sense of safety while vapours escape into the room.
OSHA's Laboratory Standard sets no universal face-velocity number for fume hoods. Typical design guidance, from ANSI/AIHA Z9.5, is an average face velocity of 80 to 120 feet per minute for normal chemical operations. The hood's own specification and the laboratory's plan govern the number for each hood.
In the United Kingdom, HSE guidance asks for an inward air speed of 0.3 to 0.5 metres per second at the sash. It asks for at least 0.5 metres per second at the opening for vapours and 1 metre per second for dust. COSHH Regulation 9 requires local exhaust ventilation, including fume cupboards, to have a thorough examination and test at least every 14 months.
The Five-Step Hood Check Before You Start

Run this check before every use, and stop work if any step fails. A hood with no airflow, a blocked baffle or a raised sash does not protect you. The experiment can wait until the hood is fixed.
- Check the airflow indicator or alarm and confirm the hood is drawing air.
- Lower the sash to the marked working height and keep it there while working.
- Set apparatus at least 15 centimetres (6 inches) back from the sash opening.
- Remove anything stored inside the hood that the procedure does not need.
- Keep your head and upper body outside the hood at all times.
Never store chemicals in a fume hood: bottles block airflow, crowd the work area and turn a small fire into a large one. Chemicals that need ventilated storage belong in a vented cabinet, not in the hood. Never evaporate chemical waste in a hood to dispose of it. Site the work away from doors and walkways, since draughts from passing people disturb the airflow and pull vapours out of the hood. If the alarm sounds or the airflow indicator fails, close the sash, stop the procedure and report the hood at once.
Storing Chemicals So They Cannot React

Chemical storage is organised by compatibility, not by alphabet. Storing chemicals alphabetically puts an acid next to a base and an oxidiser next to a flammable solvent, because their names happen to sit together. Store by hazard group instead. Keep incompatible groups on separate shelves or in separate cabinets. Keep the most hazardous chemicals in the smallest quantities the work allows.
| Keep apart | Why |
|---|---|
| Acids and bases | Violent neutralisation, heat and splashing on mixing |
| Oxidisers and flammable liquids | Oxidisers feed fire and can ignite flammables on contact |
| Water-reactive chemicals and water sources | Reaction releases flammable or toxic gas |
| Perchloric acid and organic material | Explosive perchlorates form on contact with organics |
| Compressed gases by type | Flammable and oxidising gases must not share a store |
Flammable liquids belong in a listed flammable-storage cabinet or a safety can, away from heat, ignition sources and exits. NFPA 45, the US standard for fire protection in laboratories using chemicals, caps a Class A laboratory — the highest fire hazard class — at 10 gallons of Class I flammable liquid per 100 square feet in use, or 20 gallons of Class I, II and IIIA combined. Those limits double when the liquids sit in safety cans or listed cabinets. Lower classes carry lower limits, and the edition of the standard adopted for the building governs the exact numbers.
Date peroxide-forming chemicals such as ethers and tetrahydrofuran on receipt and on first opening. Dispose of them before the date on the label passes, since old peroxides can explode on handling.
Label Every Container
Every container carries a label naming its contents and its hazard, including beakers, wash bottles and samples left for later use. A label needs the chemical name, the hazard pictograms or warnings, and the date it was opened where the chemical degrades or forms peroxides. Secondary containers decanted from a stock bottle carry the same hazard information as the stock bottle. Unlabelled containers are treated as hazardous waste, because nobody can prove what is inside them.
Store liquids below eye level where possible, and keep heavy containers low. Never store chemicals on the floor, on top of cabinets or above shoulder height. Keep the stockroom cool, dry and ventilated, with secondary containment trays under liquids. Check stored chemicals regularly for leaking caps, swollen containers, crystallisation around lids and faded labels. Report anything damaged or out of date to the lab supervisor.
Handling Glassware, Sharps and Compressed Gas

Glassware, sharps and compressed gas cause a large share of laboratory injuries, and each has a simple set of rules. Glass cuts, needles puncture, and a fallen cylinder becomes a missile. Handle each one as if it will fail, and the failure becomes a report rather than an injury.
Glassware
Inspect every piece of glassware before use. Look for chips, cracks, star cracks and scratches, and discard any damaged piece in the broken-glass container, never in general waste. Never use glassware that has been repaired with tape. Heat glassware evenly, and let hot glass cool before handling. Hot glass looks exactly like cold glass, so use tongs or heat-resistant gloves, and mark hot apparatus so nobody grabs it. Lubricate glass tubing before inserting it into a stopper or tubing. Protect your hands with a cloth, and push with a twisting motion away from your body.
Carry glass bottles with two hands, one under the base, and use a carrier or bucket for large bottles of acid or solvent. Never pour from a bottle held above shoulder height. Dispose of broken glass in a rigid, labelled broken-glass container, and sweep small fragments with a brush and dustpan, never with bare hands. Vacuum flasks and desiccators under vacuum need a guard or tape, since an implosion throws glass across the bench.
Sharps
Sharps include needles, scalpel blades, broken glass, pipette tips and microtome blades. Put sharps straight into a puncture-resistant sharps container at the point of use, and never recap, bend, break or remove a needle by hand. Fill a sharps container to no more than three quarters, then seal it and arrange disposal through the laboratory's waste route. Keep the container within arm's reach of the work, so nobody carries a used sharp across the room.
Report every sharps injury at once, even a small scratch, and follow the laboratory's exposure procedure for blood or body fluid contact. Wash the wound, let it bleed briefly, cover it, and seek medical advice the same day. A sharps injury is also a near miss for the next person. Find out why it happened — a full container, a missing tray, a rushed step — and fix the cause.
Compressed Gas Cylinders
Restrain every gas cylinder upright with a chain or strap, whether it is full or empty, in use or in storage. Keep the valve cap on whenever the cylinder is not connected, and never move a cylinder without its cap. Move cylinders on a trolley designed for the job, never by rolling, dragging or dropping them. Check the label, the regulator and the connections before opening a valve, and open valves slowly, standing to one side.
Store flammable and oxidising gases apart, away from heat and ignition sources, and keep toxic gases in a ventilated store or a gas cabinet. Never oil a valve or a regulator, since oil and oxygen react violently. Never use a cylinder as a roller, a support or a doorstop. Mark empty cylinders clearly and return them to the supplier's store, so nobody connects an empty cylinder to a running procedure.
Biological Hazards and Biosafety Levels

Biological hazards include bacteria, viruses, fungi, parasites, cell cultures, blood and body fluids, and the toxins some organisms produce. Infection happens through inhalation, ingestion, skin contact or a sharps injury, and allergy and toxicity add further routes of harm. Standard microbiological practice is the baseline for all biological work. It means mechanical pipetting only, safe sharps handling, no eating or drinking, handwashing, daily decontamination of work surfaces, and decontamination of all infectious waste before disposal.
A biosafety cabinet is not a fume hood. A Class II biosafety cabinet draws air through HEPA filters to protect the worker, the work and the environment from infectious aerosols. A chemical fume hood exhausts vapours outside and gives no protection against biological agents. Use the cabinet for any procedure that can create infectious aerosols or splashes. Work in the centre of the cabinet, and never block its air grilles with equipment. Biological hazards in depth cover the agents, the routes of exposure and the controls in full.
Biosafety Levels Bsl-1 to Bsl-4

Biosafety levels run from BSL-1 to BSL-4, each adding practices, containment equipment and facility controls to the level below. The level is set by risk assessment for a specific protocol, not by the name of the organism alone. The CDC and NIH Biosafety in Microbiological and Biomedical Laboratories (BMBL), 6th edition, is the reference that defines them. BMBL is advisory best practice rather than a standalone regulation, though other frameworks incorporate it by reference.
| Level | Agents | Key controls |
|---|---|---|
| BSL-1 | Well-characterised agents not known to cause disease in healthy adults | Open bench, standard practice, handwashing sink |
| BSL-2 | Moderate-hazard agents, e.g. Staphylococcus aureus | Restricted access, biohazard signs, Class II cabinet for aerosols, self-closing doors |
| BSL-3 | Agents causing serious or lethal disease by inhalation, e.g. Mycobacterium tuberculosis | Directional airflow, sealed room, double-door entry, HEPA-filtered exhaust, cabinet work |
| BSL-4 | Dangerous or exotic agents with high individual and community risk | Maximum containment, Class III cabinet or positive-pressure suit |
Most diagnostic and teaching laboratories work at BSL-2, the level most readers will meet. Work at BSL-2 adds restricted access while work is under way, biohazard warning signs at the entrance, a written biosafety manual, and a Class II biosafety cabinet for aerosol-generating procedures. Read the BSL-2 page for the full requirements of that level, including the cabinet classes and the facility features. BSL-3 and BSL-4 work needs specialist facilities, trained staff and, for select agents, federal registration.
Eyewash Stations and Safety Showers

OSHA's medical services and first aid standard, 29 CFR 1910.151(c), requires suitable facilities for quick drenching or flushing of the eyes and body wherever eyes or body may be exposed to injurious corrosive material. That covers most chemistry laboratories. The regulation itself gives no flow rates, temperatures or distances. Those numbers come from ANSI/ISEA Z358.1, the standard OSHA treats as the recognised guide for what "suitable" looks like.
Under ANSI/ISEA Z358.1-2014, an eyewash must deliver 0.4 gallons per minute to both eyes for at least 15 minutes. A safety shower must deliver 20 gallons per minute for at least 15 minutes. The flushing fluid must be tepid, 60 to 100 °F (16 to 38 °C), so a person can stand under it for the full 15 minutes without scalding or hypothermia.
Equipment must sit within 10 seconds of travel, about 55 feet, on the same level as the hazard. The path to it must stay unobstructed. Valves must open within one second and stay open without being held, so both hands are free to hold the eyelids open.
WarningA squeeze bottle of eyewash is a supplement, never a replacement for a plumbed eyewash station. It cannot deliver 0.4 gallons per minute for 15 minutes, and it leaves one hand busy squeezing instead of holding the eyelids open.
What to Do at the Eyewash

Speed matters more than anything else after a splash. The first 10 to 15 seconds decide how much damage a chemical does to the eye. Know the route to the nearest eyewash before you start work, and keep the path clear. Weekly activation of eyewash units proves the water flows and flushes stagnant water from the pipes. Report a unit that has not been tested.
- Get to the eyewash at once and activate it with one movement.
- Hold both eyelids open with your fingers so water reaches the whole eye.
- Flush for a full 15 minutes, rolling your eyes so water reaches every surface.
- Remove contact lenses while flushing if they do not wash out on their own.
- Get medical help after flushing, and take the chemical's label or SDS with you.
For a body splash, use the safety shower the same way. Pull the handle, stand under the water for 15 minutes, and remove contaminated clothing while under the shower. Modesty can wait; chemical burns cannot. A colleague should call for help and bring the SDS while the affected person stays under the water. First aid kit contents and the laboratory's first-aiders cover the smaller injuries that do not need the shower.
Fire in the Lab

Fire in a laboratory starts the same way it starts anywhere else: fuel, oxygen and an ignition source meeting at the wrong moment. Laboratories hold more of all three than most workplaces. Flammable solvents, open flames, hot plates, electrical equipment and oxidisers sit within a few feet of each other. Control the fuel and the ignition sources, and most lab fires never start.
NFPA 45, the US standard on fire protection for laboratories using chemicals, sorts laboratory units into fire hazard classes A to D. The sorting rests on the quantities of flammable and combustible liquids stored and used. Class A is the highest hazard and Class D the lowest. The class drives the construction, separation, sprinkler and egress requirements for the laboratory. Keep flammable liquids in rated cabinets or safety cans, away from heat and ignition sources. Never heat a flammable solvent with an open flame; use a water bath, heating mantle or hot plate instead.
Know the location and the type of the nearest fire extinguisher before starting work, and know which fires it can fight. A carbon dioxide or dry-powder extinguisher suits most lab fires. Water must never be used on an electrical fire or a flammable-liquid fire. Use an extinguisher only on a small fire in its early stage. Keep your back to the exit, with an escape route behind you.
If the fire grows, if smoke fills the room, or if you are unsure, leave at once. Close the door, raise the alarm and call the fire service. Fire extinguisher classes explain which extinguisher matches each class of fire, and practice emergency procedures keep the escape route familiar before it is needed.
WarningNever use water on a burning metal or a flammable-liquid fire. Water spreads burning liquid and reacts violently with burning metals. Use the correct extinguisher, or leave and raise the alarm.
Spills — What to Do First

A spill is a small emergency, and the first minute decides whether it stays small. Alert the people nearby, protect yourself, and contain the spill before it spreads to drains, walkways and other benches. A spill kit, absorbent material, protective equipment and the SDS for the chemical involved must be within reach before the work starts. They must not be fetched after the bottle breaks.
Only clean up a spill you are trained and equipped for. A small spill of a low-hazard chemical, with the right spill kit and protective equipment, is a job for the trained worker at the bench. A large spill, a highly toxic or volatile chemical, a spill involving broken glass and a reactive chemical, or any spill you are unsure about, is a job for the laboratory supervisor, the Chemical Hygiene Officer or the emergency team. Never try to evaporate chemical waste in a fume hood to dispose of it.
The Spill-Response Steps

Follow these steps in order. The order matters: protecting people comes before protecting property, and containing the spill comes before cleaning it up. A spill that reaches a drain or a corridor is no longer a bench problem.
- Alert everyone nearby and move people away from the spill.
- Put on the protective equipment the SDS names for that chemical.
- Contain the spill with absorbent material and keep it out of drains.
- Clean up with the spill kit, starting from the outside edges inward.
- Bag the waste, label it, and report the spill to the supervisor.
Read the SDS before cleaning up: it names the protective equipment, the absorbent material and the disposal route for that chemical. Ventilate the area, and keep ignition sources away from flammable spills. Wash the area and your hands after the clean-up, and restock the spill kit. Record the spill in the laboratory's incident log. A spill that is not recorded is a lesson nobody learns from.
The Law — US and UK Side by Side

Lab safety law differs by country, and the same laboratory can sit under different rules depending on where it stands. The United States and the United Kingdom both require a written plan and a risk assessment before hazardous work begins. They name them differently and enforce them through different regulators.
| United States | United Kingdom | |
|---|---|---|
| Main law | OSHA Laboratory Standard, 29 CFR 1910.1450 | Health and Safety at Work etc. Act 1974; COSHH Regulations 2002 |
| Written plan | Chemical Hygiene Plan, eight required elements | COSHH risk assessment before work begins |
| Named person | Chemical Hygiene Officer | Competent person for the assessment |
| Labels and data sheets | Hazard Communication Standard, 29 CFR 1910.1200 | GB CLP Regulation; safety data sheets |
| Biological containment | BMBL biosafety levels BSL-1 to BSL-4 | COSHH Schedule 3 containment levels CL2 and CL3 |
| Ventilation checks | CHP must ensure hoods function properly | LEV thorough examination at least every 14 months |
In the United States, the Laboratory Standard applies where hazardous chemicals are used on a laboratory scale. It replaces most other OSHA health standards for laboratory work, keeping only the exposure limits and the bans on eye and skin contact. The Hazard Communication Standard, 29 CFR 1910.1200, supplies the labels and safety data sheets.
In the United Kingdom, the Control of Substances Hazardous to Health Regulations 2002 (COSHH) require a formal, documented risk assessment before work with hazardous substances begins. Schedule 3 sets containment levels for biological agents: restricted access, disinfection, safe storage and safety cabinets at CL2, and separation, HEPA-filtered extract, negative pressure and a sealable room at CL3. Check which edition of each standard and code your building and your regulator follow. Editions differ, and jurisdictions adopt them at different times.
Frequently Asked Questions
Can I Wear Contact Lenses in the Lab?
Yes, but contact lenses are not eye protection. Wear safety glasses or goggles over them, and tell your supervisor you wear lenses so first aid can account for it. Lenses can trap a chemical against the eye. Remove them while flushing at the eyewash if they do not wash out on their own.
How Long Should I Flush My Eyes After a Chemical Splash?
Flush for a full 15 minutes with tepid water, holding both eyelids open and rolling your eyes so water reaches every surface. The 15-minute flush and the 0.4 gallons per minute flow come from ANSI/ISEA Z358.1. The eyewash must sit within 10 seconds of the hazard. Get medical help after flushing, and take the chemical's label or SDS with you.
What is the Difference Between a Fume Hood and a Biosafety Cabinet?
A chemical fume hood draws vapours away from the worker and exhausts them outside the building, protecting against chemical exposure. A Class II biosafety cabinet draws air through HEPA filters to protect the worker, the work and the environment from infectious aerosols. A fume hood gives no protection against biological agents, and a biosafety cabinet is not designed for volatile chemicals.
Can I Eat or Drink in the Lab?
No. Food, drink, chewing gum and cosmetics are not allowed in a laboratory, and food is never stored in a laboratory refrigerator. Food and drink absorb vapours and can be mistaken for reagents. Eat and drink outside the laboratory, and wash your hands before leaving.
How Often Must a Fume Hood Be Tested?
Check the airflow indicator before every use, and follow the laboratory's Chemical Hygiene Plan for scheduled testing. In the United Kingdom, COSHH Regulation 9 requires local exhaust ventilation to have a thorough examination and test at least every 14 months. That includes fume cupboards. Report a hood with no airflow or a failed alarm at once.
WHO Writes the Chemical Hygiene Plan?
The employer writes it. A named Chemical Hygiene Officer, qualified by training or experience, gives technical guidance on it. The plan must be reviewed and evaluated at least once a year and updated as needed. Every worker in the laboratory must know where the plan is kept and what it requires of them.
Sources
- OSHA — 29 CFR 1910.1450, Occupational Exposure to Hazardous Chemicals in Laboratories (Laboratory Standard)
- OSHA — Laboratory Safety: Chemical Hygiene Plan, Fact Sheet FS-3461
- Federal Register — Technical amendment updating Appendix A of 29 CFR 1910.1450 to the 2011 Prudent Practices in the Laboratory
- OSHA — 29 CFR 1910.151, Medical Services and First Aid
- OSHA — 29 CFR 1910.1200, Hazard Communication
- OSHA — 29 CFR 1910.132, General Requirements (Personal Protective Equipment)
- OSHA — 29 CFR 1910.157, Portable Fire Extinguishers
- NFPA — NFPA 45, Standard on Fire Protection for Laboratories Using Chemicals (2024 edition)
- CDC/NIH — Biosafety in Microbiological and Biomedical Laboratories (BMBL), 6th edition
- HSE — COSHH Essentials: Laboratory Practice (OCE17)
- Legislation.gov.uk — Control of Substances Hazardous to Health Regulations 2002 (COSHH)
- Lab Manager — Safety Shower and Eyewash Requirements: ANSI/ISEA Z358.1 (summary of the standard's figures)
